IEC Elektrikoa | 75 | 150 | 275 | 320 | ||
AC tentsio nominala (50/60Hz) | Uc/Un | 60V | 120V | 230V | 230V | |
Etengabeko funtzionamendu-tentsio maximoa (AC) | (LN) | Uc | 75V | 150V | 270V | 320V |
(N-PE) | Uc | 255V | ||||
Deskarga-korronte nominala (8/20μs) | (LN)/(N-PE) | In | 20 kA/25kA | |||
Deskarga-korronte maximoa (8/20μs) | (LN)/(N-PE) | Imax | 50 kA/50 kA | |||
Bulkada Deskarga Korrontea (10/350μs) | (LN)/(N-PE) | Iimp | 12,5kA/25kA | |||
Energia espezifikoa | (LN)/(N-PE) | W/R | 39 kJ/Ω / 156 kJ/Ω | |||
Kargatu | (LN)/(N-PE) | Q | 6,25 As/12,5A | |||
Tentsioaren babes-maila | (LN)/(N-PE) | Up | 0,7kV/1,5 kV | 1,0kV/1,5 kV | 1,5 kV/1,5 kV | 1. 6kV/1,5 kV |
(N-PE) | Ifi | 100 BESOA | ||||
Erantzun Denbora | (LN)/(N-PE) | tA | <25ns/<100 ns | |||
Ordezko Fusiblea (gehienez) | 315A/250A gG | |||||
Zirkuitu laburreko korronte balorazioa (AC) | (LN) | ISCCR | 25kA/50kA | |||
TOV jasan 5s | (LN) | UT | 114V | 180V | 335V | 335V |
TOV 120min | (LN) | UT | 114V | 230V | 440V | 440V |
Modu | Jasaten | Huts segurua | Huts segurua | Huts segurua | ||
TOV jasan 200 ms | (N-PE) | UT | 1200V | |||
UL Elektrikoa | ||||||
Etengabeko funtzionamendu-tentsio maximoa (AC) | MCOV | 75V/255V | 150V/255V | 275V/255V | 320V/255V | |
Tentsioaren babesaren balorazioa | VPR | 330V/1200V | 600V/1200V | 900V/1200V | 1200V/1200V | |
Deskarga-korronte nominala (8/20μs) | In | 20kA/20kA | 20kA/20kA | 20kA/20kA | 20kA/20kA | |
Zirkuitu laburreko korronte balorazioa (AC) | SCCR | 100kA | 200kA | 150kA | 150kA |